SHOP

 


  • Interface, Measurement & Control Relays
  • Push buttons, Switches, Pilot Lights & Joysticks
  • Inductive & Capacitive Sensors
  • Medium Voltage Distribution and Grid Automation
59642 | Schneider Electric ACE949-2 RS485 Interface Module for Sepam Series 20/40/60/80 – Modbus RTU Communication
Schneider Electric ACE949-2 is a high-performance RS485 communication interface designed for Sepam Series 20, 40, 60, and 80 digital protection relays. Featuring Modbus RTU protocol support over E-LAN and S-LAN, this module ensures seamless integration of Sepam devices into your monitoring and control systems. With a wide supply voltage range of 12/24V DC, robust mechanical resistance, and LED status indication, it is ideal for industrial applications demanding reliability and clear communication.
14,125.00 EGP 14125.0 EGP
59704 | Schneider Electric base unit SEP383 for Sepam series 80 - 24…250 V - with advanced UMI
Sepam series 80
SEP383

UMI indication:
-Status of logic inputs
-Logipam data
-Metering and diagnosis data
-Main protection settings
-Version of Sepam and remote modules
-List of activated protection functions
-Alarms and operating messages

UMI control:
Alarm acknowledgement
Output testing
Sepam reset

128 x 64 pixels
Number of key 9
2 LEDs for Sepam operating status (back part)
2 LEDs for Sepam operating status (front face)
9 LEDs for indication of parameters (front face)
14,125.00 EGP 14125.0 EGP
Schneider Electric Sepam S82 Protection Relay
Product Type: Digital Protection Relay
Model: Sepam S82
Application: Substation and industrial distribution protection
Manufacturer: Schneider Electric

Protection Functions:
Phase Overcurrent (50/51)
Ground Overcurrent (50N/51N)
Negative Sequence Overcurrent (46)
Thermal Overload Protection (49)
Breaker Failure Protection (BF)
Remote Trip Function (RTr)

Measurement & Metering:
RMS current measurement for each phase and neutral
Peak demand metering
Real-time and historical fault records

Control Capabilities:
Trip commands to circuit breakers
Status supervision of breakers and isolators
Time tagging of events and alarms

Communication:
Modbus RTU and IEC 870-5-103 protocols (standard)

Modbus TCP/IP and IEC 61850 with communication modules

Display & Interface:
Built-in LCD for local parameter display
LED indicators for protection trip/alarm

Mounting:
Flush-mounted in control panel
Optional remote HMI (MIU)

Auxiliary Power Supply:
24–250 V DC or 48–230 V AC

Operating Conditions:
Operating Temperature: –10°C to +60°C
Protection Class: IP52 (front), IP20 (rear)
141,250.00 EGP 141250.0 EGP